Skip to main content

Modules

Ten modules. One governed record.

Each module writes into the same central geotechnical database under the same four-layer conformance checking. Nothing runs on a private copy of your data.

M01 · Field

BS 5930 · AGS 4.1

Field logging

Capture once, at source

Drilling records, strata descriptions, sampling, and groundwater readings entered on the rig against location and depth interval — offline-tolerant, synced into the central database on connection.

  • Offline-first daily records
  • BS 5930 description builder
  • Photo & core box attachments
  • Rig, crew, and shift logging

M02 · Field

ASTM D1586 · Eurocode 7 · BS EN ISO 22476-3

In-situ testing & engineering intelligence

Every increment, corrected and bound to depth

SPT, CPT, permeability, and pressuremeter records remain tied to location and depth while G& standardises SPT N60 and (N1)60, preserves refusal logic, and supports characteristic parameter review by stratum.

  • SPT N60 & (N1)60 standardisation
  • Refusal-aware depth profiles
  • Characteristic parameter review
  • Ground-hazard screening

M03 · Database

AGS 4.1 · BS EN ISO 14688 / 14689

Central geotechnical database

One governed estate

Projects, areas, locations, strata, samples, in-situ tests, lab results, and groundwater observations in a strict parent–child schema, with referential integrity enforced at the database itself.

  • Portfolio → project → area → location
  • Referential integrity at the database
  • Versioned standards as data
  • Full record history

M04 · Database

AGS 4.1

Data intake & AGS workspace

Every source enters one governed record

Field records, handwriting, legacy AGS, and Excel enter through one controlled intake path. Files are inspected, mapped, and checked without creating a parallel copy of the project record.

  • AGS 3 / 4 inspection
  • Excel-to-AGS compilation
  • Handwriting OCR review
  • Lossless import manifests & diffs

M05 · Laboratory

BS 1377 · ASTM

Laboratory lifecycle

Request to result, one record

Request, schedule, test, calculate, check, approve, report — the full lifecycle on the sample record, with results autofilled back into logs and report tables.

  • Scheduling & capacity view
  • Forward-only status ladder
  • Checker and signing engineer roles
  • Result autofill into logs

M06 · Laboratory

Contract rate schedules

Quantities & IPC

Billed from approved records

Interim payment statements built directly from approved records — quantities your client can trace to the borehole, the sample, and the test. No re-entry, no reconciliation.

  • Quantity statements from approved data
  • IPC generation & revisions
  • Rate schedules per contract
  • Client-traceable line items

M07 · Output

BS 5930 · BS 1377

Deliverables & factual reconciliation

Publication-grade, reconciled to the record

Borehole logs and factual report drafts are drawn from approved records. The beta review workflow reconciles report statements, investigation counts, drilled depths, refusal tallies, recovery, and laboratory schedules against the underlying data.

  • Factual report drafting
  • Report-to-record reconciliation · beta
  • BOQ census & variance review · beta
  • Comment response sheets · beta

M08 · Output

Eurocode 7 · IFC 4.3 · LandXML 1.2

Subsurface intelligence & exchange

Ground truth, modelled without invented geology

Engineering charts, elevation-referenced borehole profiles, groundwater and rock-head surfaces, and 3D exchange outputs are generated from the governed record. G& does not interpolate geology where evidence is absent.

  • 3D borehole & stratum views
  • LandXML 1.2, IFC 4.3 & DXF export
  • Groundwater & rock-head surfaces
  • Non-interpolated ground profiles

M09 · Governance

AGS 4.1 · Client submission specs

Submission control

Nothing leaves unchecked

Four-layer conformance checking, client-specific submission rules, an issue log with corrections, and a go / no-go readiness view per area before anything leaves the building.

  • Four-layer conformance-check engine
  • Client rule sets
  • Issue log & corrections
  • Submission package assembly

M10 · Governance

ISO 9001-aligned workflows

Roles, audit & hosting

Tender-grade accountability

Role-based access across project engineer, data coordinator, QA reviewer, project manager, and admin — with every import, conformance check, approval, and export audit-logged.

  • Role-based access control
  • Immutable audit log
  • Regional & sovereign hosting
  • Signed approval records

Conformance checking, in place

Every module reports into the same issue log.

A flag raised in the laboratory module is the same flag the QA reviewer clears and the project manager sees on the readiness view.

Book a Demo
Issue log
OpenIn correctionClearedRules
RefLayerRecordRaised bySeverity
IS-241L2 Engineering logicBH-115/S11EngineBlocker
IS-238L1 Data integrityBH-107 depthsEngineError
IS-231L3 AGS 4.1 reference checksLBST parent refEngineError
IS-226L4 PlausibilityGW vs. drillingQA reviewerWarning
49 open · assigned by role · every transition logged